Once having been set, the innovative fan-shaped driver never fails to return to where the pipette tip is supposed to be. The newly installed knob allows a pipette to move along its axis by using traditional and smooth oil hydraulic joystick. This manipulator will spare the laborious work of a pipette alignment with the optical axis, providing more time for objective operation.
* This product is sold in the set of both handed manipulators and a dedicated adaptor.
* A microscope and injectors (IM-11-2) are not included.
The injection holder is provided with an anchor (special clasp) that fits in the driver body, which enables a distance from a pipette tip to the anchor to be in a length. This function can be used for memorizing a regular position so that time for a pipette exchange will reduce and repeated pipette location is precise and stable.
* Design tolerance for attachment of a pipette is 10mm. Pipette location can be corrected within the tolerance so that it can be attached as usual manner.
The pipette tip is designed for staying at the optical axis against any angles. So angle adjustment is hard to miss the tip in the field of view.
15° | 40° |
---|
50mm retracting margin enables easy exchange of a pipette. Breakage of pipettes is greatly reduced during the replacement.
Home position | Working position |
---|
A dedicated adaptor for each microscope has been developed. It needs no adjustment for mounting so that it can be installed at best position without fail. Find an appropriate adaptor in the following table.
Supplier | Microscope | Model |
---|---|---|
Evident (Olympus) | IX71 | MTK-1-O2 |
IX73, IX83 | MTK-1-O3 | |
Nikon | ECLIPSE Ti | MTK-1-N2 |
ECLIPSE Ts2R | MTK-1-N3 | |
ECLIPSE Ti2 | MTK-1-N4 | |
Carl Zeiss | Axiovert 200, Axio Observer 3/5/7 | MTK-1-Z1 |
Axio Vert.A1 | MTK-1-Z2 | |
Leica | DMi8 | MTK-1-L2 |
* In the event a special adaptor is required except for the above table, depending on the specifications of a stage, a plate insert, or thermos-plate, please contact Narishige for more information.
Accessories included | Dedicated Mounting Adaptor IP Iron Plate × 2 units Positioning Gauge Anchor × 2 units Hex Wrench Pipette Scale × 2 sheets |
|
---|---|---|
Movement range | X/Y/Z-axis | Oil hydraulic control 10mm
Full rotation of knob 250µm Minimum graduation 5µm |
T-axis (for holder) |
Oil hydraulic control 10mm Full rotation of knob 1,000µm Minimum graduation 20µm |
|
Manual (Return and Home position) 50mm | ||
Incident angle 15 ~ 40° | ||
Dimensions/Weight | Control unit | W85.6 × D225 ~ 235 × H151 ~ 171mm, Approx. 1.9kg |
Drive unit | W108 ~ 138 × D145 ~ 155 × H100 ~ 150mm, Approx. 820g | |
Hydraulic tube length | 0.9m |